DC Audits & Health Checks
Why Audits/Health Checks
-
Acts as a basic quality check of Infrastructure ​
-
Helps to decide DC still meet objectives​
-
Ensures DC compliant with current standards​
-
Is Infrastructure still appropriate to meet business demands​​
-
Identify and mitigate risks/issues
Our Approach​

Requirement Analysis
-
Understand objectives and design​
-
Application Infrastructure Requirements​
-
Customer Inputs on Issues and risks​
-
Road map (if there are any changes)


Site Audit​
-
A detailed analysis of the building to ensure that it meets the minimum requirements and identify any risks ​
-
Environmental ​
-
Structural, Architecture and Space​
-
Electrical and Mechanical ​
-
Safety and Security​
Components Focused
Architecture and Space Planning​
-
Site and Geographical suitability check​
-
Civil and Structural​
-
Service Segmentation ​
-
Space Allocation​
-
Rack layout​
-
CRAC/PAC Layout​
-
Raised floor and Suspended ceiling​
-
Cable duct layout – Network & Power​
​
Mechanical Engineering​
-
CRAC Sizing and Configurations​
-
Thermal Imaging​
-
Heat Exchanger, Cooling Towers ​
-
Plumbing ​
-
Leak Detection ​
​Electrical Engineering​
-
Utility Sizing and Configurations​
-
Distribution Sizing and Redundancy Planning​
-
UPS & Battery Sizing and Configurations​
-
Circuit Sizing and Distribution Planning​
-
Grounding Design ​
-
ATS and EPS Design ​
-
PDU sizing and configuration​
-
Backup Generator Sizing​
​
​
Safety and Security Infrastructure​
Cabling – Fiber and Copper​
Racks and accessories​
Labeling and documentation​
Monitoring and alerting​
Remote Infrastructure management



Validation​
Data center is validated using​
-
Data Center standards​
-
Thermal Imaging​
-
CFD Analysis​
-
Electrical Analysis​
Realtime Thermal Imaging
Realtime thermal imaging of a brownfield data center helps in identifying hotspots, mixing and irregularities of the mechanical infrastructure.​

CFD Analysis​

Computational Fluid Dynamics Modeling - CFD​
A powerful 3D CFD tool is utilized to analyze ​
-
Total heat load and HVAC sizing​
-
Thermal mapping ​
-
Airflow and Static Pressure ​
-
Rack Inlet and Outlet Temperatures​
​
​
CFD modeling based Design​
-
Ability to develop multiple design options quickly, results in an optimal design based on a methodical process instead of a tentative approach​​
-
Saves CAPEX & OPEX and saves time by avoiding mistakes​
-
Modeling of multiple loading scenarios helps in determining scalability and individual rack loading plans throughout the life cycle
Electrical analysis​
Following analysis are carried out at site for improving
PUE of the data center​
​
-
Real-time racks load analysis​
-
Review for used power in racks​
-
Mechanical infrastructure power usage​
-
Redundancy​


Standards adhered
Uptime Institute / TIA​
ASHRAE​
IEEE​
Local building and fire codes​
ISO​