top of page

DC Audits & Health Checks

Why Audits / Health Checks

  • Acts as a basic quality check of Infrastructure ​

  • Helps to decide DC still meet objectives​

  • Ensures DC compliant with current standards​

  • Is Infrastructure still appropriate to meet business demands​​

  • Identify and mitigate risks/issues

Our Approach

Requirement Analysis

  • Understand objectives and design

  • Application Infrastructure Requirements​

  • Customer Inputs on Issues and risks​

  • Road map (if there are any changes)

Let's Work Together

Corporate Address:

Plot No. D-5, 91 Springboard Business Hub Private Limited, Road No. 20, Marol MIDC, Andheri East, Mumbai Suburban, Maharashtra, 400093

Tel: +91 9341787205, +91 9582892896
 

Branch Address:

Plot 12C, 1, 3rd Cross St, South Phase, Guindy Industrial Estate, Industrial Estate, Guindy, Chennai, Tamil Nadu 600032

Tel: +91 9500123194
 

Regional Address:

71-75 Shelton Street, Convent Garden,

London, United Kingdom - WC2H9JQ

  • LinkedIn
  • X

Components Focused

Architecture and Space Planning​

  • Site and Geographical suitability check​

  • Civil and Structural​

  • Service Segmentation ​

  • Space Allocation​

  • Rack layout​

  • CRAC/PAC Layout​

  • Raised floor and Suspended ceiling​

  • Cable duct layout – Network & Power​

 

Mechanical Engineering​

  • CRAC Sizing and Configurations​

  • Thermal Imaging​

  • Heat Exchanger, Cooling Towers ​

  • Plumbing ​

  • Leak Detection ​

 

 

Electrical Engineering​

  • Utility Sizing and Configurations​

  • Distribution Sizing and Redundancy Planning​

  • UPS & Battery Sizing and Configurations​

  • Circuit Sizing and Distribution Planning​

  • Grounding Design ​

  • ATS and EPS Design ​

  • PDU sizing and configuration​

  • Backup Generator Sizing​

Safety and Security Infrastructure​

Cabling – Fiber and Copper​

Racks and accessories​

Labeling and documentation​

Monitoring and alerting​

Remote Infrastructure management

Validation

Data center is validated using​

  • Data Center standards​

  • Thermal Imaging​

  • CFD Analysis​

  • Electrical Analysis​

Realtime Thermal Imaging

Realtime thermal imaging of a brownfield data center helps in identifying hotspots, mixing and irregularities of the mechanical infrastructure.​

CFD Analysis

Computational Fluid Dynamics Modeling - CFD​

A powerful 3D CFD tool is utilized to analyze ​

  • Total heat load and HVAC sizing​

  • Thermal mapping ​

  • Airflow and Static Pressure ​

  • Rack Inlet and Outlet Temperatures​

CFD modeling based Design

  • Ability to develop multiple design options quickly, results in an optimal design based on  a methodical process instead of a tentative approach​​

  • Saves CAPEX & OPEX and saves time by avoiding mistakes​

  • Modeling of multiple loading scenarios helps in determining scalability and individual rack loading plans throughout the life cycle   

Electrical Analysis

Following analysis are carried out at site for improving

  PUE of the data center​

  • Real-time racks load analysis​

  • Review for used power in racks​

  • Mechanical infrastructure power usage​

  • Redundancy​

Standards Adhered

Uptime Institute / TIA​

ASHRAE​

IEEE​

Local building and fire codes​

ISO​

Site Audit

  • A detailed analysis of the building  to ensure that it meets  the minimum requirements and identify any risks ​

  • Environmental ​

  • Structural, Architecture and Space​

  • Electrical and Mechanical ​

  • Safety and Security

bottom of page